Worldwide delivery - Large stock
Legrand/Imesys

Three-Phases energy meter 63A Dual tariff RS485 Modbus MID - Conto D4 - CE4DF3DTMID

IME-412093

€172.64 Excl. Tax
€207.17 Inc. Tax
available In stock – Dispatched within 24/48h
  • check2 Technical support and dedicated single point of contact
  • check2 Free delivery from 200€ of purchase (Metropolitan France)
  • check2 100% secure payments maestro mastercard visa payplug applepay
Technical informations

Product Description

The Imesys Conto D4 Energy Meter is designed for three-phase or 4-wire networks up to 63A, with MID certification. This meter measures and displays positive and negative active and reactive energies, and is equipped with a double tariff or pulse output. With Modbus RTU communication via RS485, it is possible to transmit and display all electrical parameters in addition to energy consumption.


Technical Specifications

Specifications CE4DF3DTMID (63A)
Input Current  
Starting current (Ist) 0.02A
Minimum current (Imin) 0.25A
Basic current (Ib) 10A
Maximum current (Imax) 63A
Short-time overcurrent 20Imax/0.5s 30Imax/0.5s
Power consumption 2.2VA / 1.5W three-phase
Input Voltage  
Reference three-phase voltage (with N) 230V ±10%
Reference three-phase voltage (without N) 400V ±10%
Network  
Reference frequency 50Hz ±1Hz / 60Hz ±1Hz
Frequency tolerance 49.5Hz – 61.5Hz
Auxiliary Supply  
Nominal voltage Taken from measurement (self-supplied)
Accuracy  
Active energy kWh EN50470 cl. B
Reactive energy kvarh EN/IEC 62053-23 cl. 2
Display  
Type Backlit Graphic LCD
Display size 2"
Energy resolution 9999999.99 kWh
Mechanical Features  
Housing 4 modules DIN 43880 (35mm)
Housing material Polycarbonate >PC<
Heat resistance 850°C
Protection degree IP20 terminals / IP54 front frame
Sealable terminals Yes
Connection type Screw terminals
Cable with lug Output - max 1mm² / Input - max 16mm²
Flexible cable Output - max 2.5mm² / Input - max 10mm²
Environmental Conditions  
Nominal temperature range -25…55°C
Storage and transport temperature range -40…70°C
Suitable for tropical climates Yes
Max power dissipation ≤6W
Output  
RS485 communication Yes
Protocol Modbus RTU
Standard RS485 3-wire
Impedance 120ohm configurable via menu
Baud rate Selectable 4800...38400 bit/s
Energy pulses SO EN/IEC 62053-31 Yes
Type Optorelay with potential-free
Contact range 27Vdc / 50mA
Assignable energy Active or reactive energy
Pulse weight Selectable 1Wh/varh...10kWh/varh
Pulse duration Selectable 50...500ms
M-BUS communication Yes
Protocol M-BUS
Standard EN13757
Baud rate Selectable 300, 600, 1200, 2400, 4800, 9600
In short
SKU IME-412093
Product Name Three-Phases energy meter 63A Dual tariff RS485 Modbus MID - Conto D4 - CE4DF3DTMID
Range Conto
En savoir plus
MID Standard

Everything You Need to Know About the MID Standard for Electric Meters

Learn about the importance of the MID standard for electric meters, its requirements, and benefits.

Read more
Related Categories