Product Description

The Imesys/Legrand Conto D2 MID Energy Meter is designed for single-phase lines up to 63A. This meter measures and displays positive and negative active and reactive energies, among other parameters. It is equipped with a double tariff or pulse input. With Modbus RTU communication via RS485, it is possible to transmit and display all electrical parameters in addition to energy consumption.


Technical Specifications

Specifications CE2DF3DTCL1 (63A)
Input Current  
Starting current (Ist) 0.02A
Minimum current (Imin) 0.25A
Basic current (Ib) 5A
Maximum current (Imax) 63A
Short-time overcurrent 30Imax/10ms
Power consumption 1.5W / 4VA
Input Voltage  
Reference single-phase voltage 230V
Specified operating range ±10%
Network  
Reference frequency 50-60Hz
Frequency tolerance 49…51.5…61Hz
Auxiliary Supply  
Nominal voltage Taken from measurement (self-supplied)
Accuracy  
Active energy kWh EN50470 cl. B
Reactive energy kWh EN/IEC62053-21 cl. 2
Display  
Type Backlit Graphic LCD
Display size 1"
Energy resolution 9999999.99 kWh
Mechanical Features  
Housing 2 modules DIN 43880 (35mm)
Housing material Self-extinguishing polycarbonate >PC<
Classification V2 in accordance with UL94 standard  
Protection degree IP20 terminals / IP54 front frame
Sealable terminals Yes
Connection type Screw terminals
Cable with lug Output - max 7mm² / Input - max 16mm²
Flexible cable Output - max 2.5mm² / Input - max 10mm²
Environmental Conditions  
Nominal temperature range -25…55°C
Storage and transport temperature range -40…70°C
Suitable for tropical climates Yes
Max power dissipation ≤4W
Output  
RS485 communication Yes
Protocol Modbus RTU
Standard RS485 3-wire
Impedance 120ohm (setting by menu)
Baud rate Selectable 4800...38400 bit/s
Energy pulses SO EN/IEC 62053-31 Yes
Type Optorelay with potential-free
Contact range 27Vdc/ac - 50mA
Assignable energy Active or reactive energy
Pulse weight Selectable 1Wh/varh...10kWh/varh
Pulse duration Selectable 50...500ms
In short
SKU IME-412081
Product Name Conto D2 single-phase energy meter, 63A, MODBUS non MID dual tariff - CE2DF3DTCL1
Range CONTO
En savoir plus
MID Standard

Everything You Need to Know About the MID Standard for Electric Meters

Learn about the importance of the MID standard for electric meters, its requirements, and benefits.

Read more
Related Categories