LEGRAND/IMESYS
Conto D2 single-phase energy meter, 63A, MODBUS non MID dual tariff - CE2DF3DTCL1
IME-412081
€108.96
Excl. Tax
€130.75
Inc. Tax
Excl. Tax
Excl. Tax
Incl. Tax
Incl. Tax
You save
In stock –
Dispatched within 24/48h
- Technical support and dedicated single point of contact
- Free delivery from 200€ of purchase (Metropolitan France)
- 100% secure payments
Technical informations
Product Description
The Imesys/Legrand Conto D2 MID Energy Meter is designed for single-phase lines up to 63A. This meter measures and displays positive and negative active and reactive energies, among other parameters. It is equipped with a double tariff or pulse input. With Modbus RTU communication via RS485, it is possible to transmit and display all electrical parameters in addition to energy consumption.
Technical Specifications
Specifications | CE2DF3DTCL1 (63A) |
---|---|
Input Current | |
Starting current (Ist) | 0.02A |
Minimum current (Imin) | 0.25A |
Basic current (Ib) | 5A |
Maximum current (Imax) | 63A |
Short-time overcurrent | 30Imax/10ms |
Power consumption | 1.5W / 4VA |
Input Voltage | |
Reference single-phase voltage | 230V |
Specified operating range | ±10% |
Network | |
Reference frequency | 50-60Hz |
Frequency tolerance | 49…51.5…61Hz |
Auxiliary Supply | |
Nominal voltage | Taken from measurement (self-supplied) |
Accuracy | |
Active energy kWh EN50470 | cl. B |
Reactive energy kWh EN/IEC62053-21 | cl. 2 |
Display | |
Type | Backlit Graphic LCD |
Display size | 1" |
Energy resolution | 9999999.99 kWh |
Mechanical Features | |
Housing | 2 modules DIN 43880 (35mm) |
Housing material | Self-extinguishing polycarbonate >PC< |
Classification V2 in accordance with UL94 standard | |
Protection degree | IP20 terminals / IP54 front frame |
Sealable terminals | Yes |
Connection type | Screw terminals |
Cable with lug | Output - max 7mm² / Input - max 16mm² |
Flexible cable | Output - max 2.5mm² / Input - max 10mm² |
Environmental Conditions | |
Nominal temperature range | -25…55°C |
Storage and transport temperature range | -40…70°C |
Suitable for tropical climates | Yes |
Max power dissipation | ≤4W |
Output | |
RS485 communication | Yes |
Protocol | Modbus RTU |
Standard | RS485 3-wire |
Impedance | 120ohm (setting by menu) |
Baud rate | Selectable 4800...38400 bit/s |
Energy pulses SO EN/IEC 62053-31 | Yes |
Type | Optorelay with potential-free |
Contact range | 27Vdc/ac - 50mA |
Assignable energy | Active or reactive energy |
Pulse weight | Selectable 1Wh/varh...10kWh/varh |
Pulse duration | Selectable 50...500ms |
In short
SKU
IME-412081
Product Name
Conto D2 single-phase energy meter, 63A, MODBUS non MID dual tariff - CE2DF3DTCL1
Range
CONTO